Our site saves small pieces of text information (cookies) on your device in order to deliver better content and for statistical purposes. You can disable the usage of cookies by changing the settings of your browser. By browsing our website without changing the browser settings you grant us permission to store that information on your device. I agree

Robo'n Roll

Alarms Meaning

Drawer out of range

Internal data structure overflowed

Drawer px anomaly

The system detected an RFID badge without a click from the shelf's px sensor. Check for metallic object int sensor path. A malfunction of the shelf's px sensor may cause this issue.

RFID anomaly, chained failures

The system detected a click from the shelf's px sensor without detecting any RFID badge for three time in a row. RFID detector may be malfunctioning.

RFID anomaly, error during initializzation

The system detected a click form the shelf's px sensor without detecting an RFID badge during initializzation. Verify that every shelf has a badge mounted. A badge might be broken or the RFID detector might be malfunctionig.

Drawer overload

Shelf's weight is exceeding the safety level. Remove some object from it.

Motor overload

Engine current consumption is high. Check for obstruction in the shelves' path or in the chains. The main engine might ber malfunctioning.

Motor critical overload

Engine current consumption is extremely high. Check for obstruction in the shelves' path or in the chains. The main engine might ber malfunctioning.

Main Door *Endrun* and *Door Closed* sensors not responding as expected

Main Door *Endrun* and *Door Closed* sensors are both active. One of them might be malfunctioning

Main Door Cable Tension too low

The cable holding the main door seems too lose. It might be broken. The sensor checking for the cable tension might be broken as well.

Main Door Ripari Px Failure

Main door "Closed Door" is not acting as expected. It might be brroken.

Main Door might be stuck

The main door seems stuck during the closing procedure. check for obstacle in his path.

Main Door is in an unexpected status

The sensor monitoring the main door act in an unpredicted way. One of them might be broken.

Main Door Endrun sensor not responding

Main Door Endrun sensor not responding as expected. It might be broken.

Unable to load shelf list from LinuxBox

The PLC is unable to load shelf list from LinuxBox.

Main door motor malfunction

A possible malfunction of the motor connected to the main door has been detected.

Back door motor malfunction

A possible malfunction of the motor connected to the back door has been detected.

Photo Px anomaly

A click from the px of the photo position was not detected. The sensor might be broken.

Back Door *Endrun* and *Door Closed* sensors not responding as expected

Back Door *Endrun* and *Door Closed* sensors are both active. One of them might be malfunctioning

Back Door Cable Tension too low

The cable holding the main door seems too lose. It might be broken. The sensor checking for the cable tension might be broken as well.

Back Door Ripari Px Failure

Back door "Closed Door" is not acting as expected. It might be brroken.

Back Door might be stuck

The Back door seems stuck during the closing procedure. check for obstacle in his path.

Back Door is in an unexpected status

The sensor monitoring the Back door act in an unpredicted way. One of them might be broken.

Back Door Endrun sensor not responding

Back Door Endrun sensor not responding as expected. It might be broken.